Racadm设置idrac

参考文档  idrac7-8-lifecycle-controller-v2.40.40.40_Reference Guide_en-us

0、下文中账户名密码均省略-r <RAC IP address> -u root -p <password>

 

1、使用racadm远程命令

Remote RACADM usage syntax:

 racadm -r <RAC IP address> -u <username> -p <password> <subcommand> <options>

 racadm -r <RAC IP address> -i <subcommand> <options>

Security Alert: Certificate is invalid - self signed certificate

Continuing execution. Use -S option for racadm to stop execution on certificate-related errors.

使用 --nocertwarn 可以忽略警告

2、racadm help

#racadm --nocertwarn  help

3、racadm help get   获取idrac信息(也可以形成文件)

racadm get <fqdd alias>.<group>

racadm get <fqdd alias>.<group>.<object>

racadm get <fqdd alias>.<group>.<index>.<object>

racadm get -f <filename>

racadm get -f <filename> -t <filetype> -u <username> -p <password>

-l <CIFS share> -c <FQDD>

racadm get -f <filename> -t <filetype> -l <NFS share> -c <FQDD>

4、racadm get iDRAC.NIC.DNSRacName 获取idrac Name

5、racadm set iDRAC.SNMP.Alert.1.DestAddr <IP address> 设置snmp的报警地址

racadm set iDRAC.IPMILan.AlertEnable enabled设置警报为已启用

racadm eventfilters set -c idrac.alert.all -a none -n email,snmp  设置警报类型

6、racadm set iDRAC.Time.Timezone Asia/Shanghai iDRAC设置timezone

7、racadm storage get pdisks  获取磁盘信息

更多的命令可以通过帮助找到